Product Description
Dixell water chiller and heat pump controller IC208CX-11000
Dixell - IC208CX-11000 + BUZ EVO 24V MULTIFUNCTION CONTROLLER, FOR CHILLERS, HEAT PUMPS, 12/24VAC/DC, 8 RELAY OUTPUTS, 1 OR 2 CIRCUIT UP TO 4 STEPS, NO REALTIME CLOCK(RTC)
Advanced Multifunction Controller for Chiller applications
This IChill IC208CX advanced multifunction controller provides simple management and control of chillers, heat pumps and geothermal heat pump units (with solar integration and sanitary hot water production) with single or dual circuits gas and water reversibility and up to four steps. This advanced controller designed for chiller unit applications with one or two circuits, such as air/air, air/water, motor-condensing.
Includes a vibrant colour dual 4 digit display, a 6 pushbutton keyboard for simple set-up, 6 configurable probe inputs, 11 configurable digital inputs, 6 relay outputs, EEPROM memory and an accuracy of plus or minus 0.7 deg C. With combined/forced defrosting, alarm control, screw compressor management, compressor management through inverter, direct, part-winding, star-delta compressor start.
This temperature controller is also suitable for the management of solar panels, sanitary hot water production, heat recovery management, free-cooling management.
Multifunction Controller Features
Power supply 12, 24Vac/dc
Probe inputs NTC, PTC - 6 x configurable
Digital inputs Free voltage - 11 x configurable
Relay outputs 5A - 6 x configurable
Serial output TTL
LAN output
Remote display output
Display 4 digits, red LED 8.5mm high, 4 digits, yellow LED 7.5mm high
Non-volatile memory (EEPROM)
Operating temperature-10÷55°C
Relative humidity 20÷85% (no condensing)
Resolution 0.1°C 0.1 bar
Features
Management of scroll, screw and inverter compressors
Identification of the compressors to activate based on the n° of hours/start-ups
Data logger up to 100 alarms (alarm type, date, hours, machine status)
Solar panel management
Dynamic set point
Heat recovery management
Free-cooling management
Pump-down function (stop and start)
Capacity function of machine power during critical functioning conditions
Forced defrost during critical conditions
Combined defrost temperature/pressure
Sanitary hot water production
Specifications
Analogs:2 X PWM/0÷10V, 2 x 0÷10V
Buzzer:Present
Digital Inputs:Free voltage: 11 x configurable
Display:Dual with icons
Hot Key 64:Present
LAN Output:Present
Power Supply:12, 24Vac/dc
Probe Inputs:NTC, PTC: 4 x configurable - NTC, PTC, 4÷20mA, 0÷5V: 2 x configurable
Prog Tool Kit Output:Present
Real Time Clock:Optional
Relay Outputs:5A: 8 x configurable
Remote Display Output:2 X VICX620, 1 x V2I820, 1 x VTIC20
TTL Output:Present